http://rdf.ncbi.nlm.nih.gov/pubchem/patent/TW-I742281-B

Outgoing Links

Predicate Object
assignee http://rdf.ncbi.nlm.nih.gov/pubchem/patentassignee/MD5_2d4ba6b2e50fefcae1a13b759f0f208c
classificationCPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01F13-00
classificationIPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01F15-07
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01F15-02
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G06F1-16
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01N35-08
filingDate 2018-05-16-04:00^^<http://www.w3.org/2001/XMLSchema#date>
grantDate 2021-10-11-04:00^^<http://www.w3.org/2001/XMLSchema#date>
inventor http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_b3aee227a7e3e6a2eb2a8e013cc6bccf
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_b00aecf15913ecb590b2c8a31ed31781
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_55c7b1db2e781095b5dde9928bf64f97
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_4de2102deb461abeb666149fbc393eea
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_57096f0c53ea202fbc85dd153244b846
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_fdb94ba478f6e9ff8103f258f0369f8d
publicationDate 2021-10-11-04:00^^<http://www.w3.org/2001/XMLSchema#date>
publicationNumber TW-I742281-B
titleOfInvention Water sample dispenser and calibration method thereof
abstract A water sample dispenser in which a flow rate adjustment valve and a flow rate sensor are provided in series, wherein a first process of opening the flow rate adjustment valve until the volume detected by the flow rate sensor reaches a first volume and a second process of opening the flow rate adjustment valve until the volume detected by the flow rate sensor reaches a second volume are executed. Based on the first volume, the second volume, the actual amount of water sampled in the first process, and the actual amount of water sampled in the second process, two parameters are calculated that specify the linear equation that represents the relationship between the detection results of the flow rate sensor and the volume after correction. When sampling water in fixed quantities, the detection results of the flow rate sensor are corrected based on the two parameters.
priorityDate 2017-07-26-04:00^^<http://www.w3.org/2001/XMLSchema#date>
type http://data.epo.org/linked-data/def/patent/Publication

Incoming Links

Predicate Subject
isCitedBy http://rdf.ncbi.nlm.nih.gov/pubchem/patent/JP-2002059161-A
isDiscussedBy http://rdf.ncbi.nlm.nih.gov/pubchem/gene/GID63974
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID419512635
http://rdf.ncbi.nlm.nih.gov/pubchem/protein/ACCQ4R5G6
http://rdf.ncbi.nlm.nih.gov/pubchem/protein/ACCP48986
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID962
http://rdf.ncbi.nlm.nih.gov/pubchem/protein/ACCQ08DI0
http://rdf.ncbi.nlm.nih.gov/pubchem/protein/ACCQ96NK8
http://rdf.ncbi.nlm.nih.gov/pubchem/gene/GID11922

Total number of triples: 29.