http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-206772680-U

Outgoing Links

Predicate Object
assignee http://rdf.ncbi.nlm.nih.gov/pubchem/patentassignee/MD5_249af008023087b0e72da094423ea84b
classificationIPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01N1-34
filingDate 2017-05-04-04:00^^<http://www.w3.org/2001/XMLSchema#date>
grantDate 2017-12-19-04:00^^<http://www.w3.org/2001/XMLSchema#date>
inventor http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_44c12aa428251fb4b623f209be5f2070
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_b414ed295c458b04c241364e6fa2ee78
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_e286c6f57a82a2d47688ba40d52c407b
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_c00fbba4c1765a44905182a52194d8e0
publicationDate 2017-12-19-04:00^^<http://www.w3.org/2001/XMLSchema#date>
publicationNumber CN-206772680-U
titleOfInvention The equipment that acid steaming pre-treatment is carried out for sea water particle organic carbon sample
abstract The utility model discloses the equipment that acid steaming pre-treatment is carried out for sea water particle organic carbon sample, hydrochloric acid storeroom with magnet rotor is placed in magnetic stirring apparatus, the sidepiece upper end of hydrochloric acid storeroom is provided with acid-adding port, the sidepiece lower end of hydrochloric acid storeroom is provided with acid discharge valve, the monitoring mouth a of hydrochloric acid storeroom top insertion acid vapor probe is arranged on hydrochloric acid ullage, and the monitoring mouth b for inserting pH meter probe is arranged under hydrochloric acid liquid level;Horizontal parallel is provided with support platform along the upper port outward flange of hydrochloric acid storeroom, is provided with glass plate fixed mount above support platform at the upper port of face hydrochloric acid storeroom, spaced set has several piece porous glass plate from top to bottom in glass plate fixed mount;Cloche is arranged on the outside of glass plate fixed mount, air outlet valve is set on the top cover of cloche.Avoid hydrochloric acid from leaking, protect health, avoid filter membrane and paste residue problem, hydrochloric acid is easy to topple over and discharged, and acid steams effect stability, reduces experimental error.
priorityDate 2017-05-04-04:00^^<http://www.w3.org/2001/XMLSchema#date>
type http://data.epo.org/linked-data/def/patent/Publication

Incoming Links

Predicate Subject
isDiscussedBy http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID297
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID419559581
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID313
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID419557048
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID419512635
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID24503
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID962
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID419577639

Total number of triples: 22.