http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-110426421-A

Outgoing Links

Predicate Object
assignee http://rdf.ncbi.nlm.nih.gov/pubchem/patentassignee/MD5_d6a6f422b091ba12ea61d4adbf1b0e8e
classificationCPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G06F18-253
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G06N3-084
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N27-12
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01D21-02
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G06F17-18
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G06F18-2135
classificationIPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01N27-12
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G06F17-18
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G06K9-62
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G06N3-08
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01D21-02
filingDate 2019-09-09-04:00^^<http://www.w3.org/2001/XMLSchema#date>
inventor http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_7326254f6acca86ba7eaf04d5fba3f2f
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_a9dd5315137ee0f93368726cb2d5c071
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_e5750d084a3a3f2fc4d219fe78a2015f
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_59f3acbbb1352d15f36574068a6c7145
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_b7939bca681df8efc53e2f75baaecff4
http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_688599c8faa24f85f7ed114faa74d9ef
publicationDate 2019-11-08-04:00^^<http://www.w3.org/2001/XMLSchema#date>
publicationNumber CN-110426421-A
titleOfInvention A multi-component harmful gas detection device and detection method in kitchen environment
abstract The invention discloses a multi-component harmful gas detection device and detection method in a kitchen environment. The detection device includes a sampling module, a power supply module, a gas chamber and a sensor module, a signal processing module, an AD conversion module, a minimum system module of a single chip microcomputer, serial port module. When the air is fed into the gas chamber at a constant speed from the outside, the sensor can quickly stabilize, respond and restore the voltage baseline. The output voltage response can be received and processed by the single-chip microcomputer, and output three kinds of carbon monoxide, methane and formaldehyde in the mixed gas to the upper computer. Component concentration test results. The device has perfect functions, small size, convenient operation, good accuracy, stability and repeatability, and can be used as a core device in the production of harmful gas detection instruments in the kitchen environment.
isCitedBy http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-114965872-B
http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-114965872-A
http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-114002303-A
http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-114002303-B
http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-113537334-A
priorityDate 2019-09-09-04:00^^<http://www.w3.org/2001/XMLSchema#date>
type http://data.epo.org/linked-data/def/patent/Publication

Incoming Links

Predicate Subject
isCitedBy http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-205562572-U
isDiscussedBy http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID455728551
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID281
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID712
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID297
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID425901710
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID702
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID458427267
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID23978
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID418354341
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID425193155
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID783
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID419538410

Total number of triples: 43.