http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CN-108593834-B

Outgoing Links

Predicate Object
classificationCPCAdditional http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N2030-146
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N2030-067
classificationCPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N30-18
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N30-14
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N30-06
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N30-96
classificationIPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01N30-14
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01N30-06
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01N30-96
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01N30-18
filingDate 2018-04-26-04:00^^<http://www.w3.org/2001/XMLSchema#date>
grantDate 2020-04-07-04:00^^<http://www.w3.org/2001/XMLSchema#date>
publicationDate 2020-04-07-04:00^^<http://www.w3.org/2001/XMLSchema#date>
publicationNumber CN-108593834-B
titleOfInvention Ion chromatograph and sample injection method thereof
abstract The invention provides an ion chromatograph and a sample introduction method thereof. The ion chromatograph includes: the sample injection needle comprises a needle tube, an ultrasonic sheet arranged on the surface of the tube wall of the needle tube and a metal film arranged on the surface of the ultrasonic sheet, in the hydrogen peroxide injection process, the decomposition of the hydrogen peroxide is catalyzed by the metal film to generate water and oxygen, the ultrasonic sheet continuously provides ultrasonic wave to hydrogen peroxide to play a role in degassing solution, removes oxygen generated during decomposition of the hydrogen peroxide, reduces the concentration of the oxygen in the hydrogen peroxide to the range of absolute safety and stable test performance of ion chromatograph detection, therefore, the hydrogen peroxide can not oxidize a system pipeline in the ion chromatograph in the sample introduction process, prevent oxygen from blocking an ion chromatographic column in the ion chromatograph, improve the detection stability and sensitivity, and ensure the quality of production raw materials and the consistency of process tests such as production process, monitoring and the like.
priorityDate 2018-04-26-04:00^^<http://www.w3.org/2001/XMLSchema#date>
type http://data.epo.org/linked-data/def/patent/Publication

Incoming Links

Predicate Subject
isDiscussedBy http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID458431511
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID457765275
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID419523291
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID977
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID962
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID784
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID23939
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID419512635

Total number of triples: 26.