http://rdf.ncbi.nlm.nih.gov/pubchem/patent/CA-1226249-A

Outgoing Links

Predicate Object
assignee http://rdf.ncbi.nlm.nih.gov/pubchem/patentassignee/MD5_b312503d5fb78f9d7d78c88940a1558c
classificationCPCAdditional http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N2030-565
classificationCPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/G01N30-56
http://rdf.ncbi.nlm.nih.gov/pubchem/patentcpc/B01D15-206
classificationIPCInventive http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/G01N30-56
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/B01J4-00
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/B01D15-08
http://rdf.ncbi.nlm.nih.gov/pubchem/patentipc/B01D15-20
filingDate 1983-08-25-04:00^^<http://www.w3.org/2001/XMLSchema#date>
grantDate 1987-09-01-04:00^^<http://www.w3.org/2001/XMLSchema#date>
inventor http://rdf.ncbi.nlm.nih.gov/pubchem/patentinventor/MD5_7576ccb22a4ed61b9cb1939dbc1656f2
publicationDate 1987-09-01-04:00^^<http://www.w3.org/2001/XMLSchema#date>
publicationNumber CA-1226249-A
titleOfInvention Narrow bore microparticulate column packing system for chromatography
abstract Abstract Narrow Bore Microparticle Column Packing Process And Product A process for packing narrow bore chromatographic columns and the resulting product are provided. A flexible column, preferably of fused silica, of inner diameter less than 500 µ m is selected. A slurry is formed in a reservoir from a mobile solvent and par-ticles of specified diameter. For liquid chromato-graphy the particle size ranges from 3 µ m to 10 µ m; for gas chromatography the particle size ranges from 3 µ m to 100 µ m. An end restriction is placed in the end of the column to permit the flow of mobile solvent and to restrict the passage of particles out the end of the column. The reservoir is attached to the column and the slurry is flowed under pressure into the column. A two-step pressure sequence is used to first set up the bed of particles and then to compress the bed. First, an initial pressure is maintained for an initial period, preferably less than 10 minutes. Next, the pressure is raised from the initial pressure to a maximum pressure and is maintained at the maximum pressure for a second period. The product in either case is a stable, loose packed column having a high plate number per unit length.
priorityDate 1982-10-04-04:00^^<http://www.w3.org/2001/XMLSchema#date>
type http://data.epo.org/linked-data/def/patent/Publication

Incoming Links

Predicate Subject
isDiscussedBy http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID408414640
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID18373917
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID451679761
http://rdf.ncbi.nlm.nih.gov/pubchem/substance/SID457707758
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID24261
http://rdf.ncbi.nlm.nih.gov/pubchem/compound/CID5954

Total number of triples: 23.